  • Typical cost: about $300 to $650 for a ridge vent in cost guides, with most around $500; soffit intake about $315 to $465.
  • Time on the roof: one to two days for a ridge vent job.
  • Code ratio: 1 square foot of net free vent area per 150 square feet of attic, or 1 per 300 when the vents are split between high and low.
  • Spray foam option: about $1.50 to $5.00 per square foot for an unvented attic.

Pompano Metal Roofing sends a local roofer your way to look at metal roof ventilation: the ridge vent, the soffit intake and the insulation that decide how hot and damp the attic under your panels gets. The referral is free.

Metal Roof Ventilation Options for South Florida Attics

Florida Solar Energy Center research puts the roof and attic at roughly a fifth of what a house's air conditioner has to remove. Ventilation is one way to cut it, and a sealed, insulated attic is the other. Which one fits depends on the house, and a metal roof has a few details of its own at the ridge and the eaves.

Vented ridge cap along the peak of a white standing seam metal roof with a profiled closure strip visible at the open end

Ridge Vents Under a Metal Ridge Cap

On a metal roof the ridge vent sits under the ridge cap and lets hot attic air out along the whole peak. In Broward's hurricane zone, a ridge vent has to carry its own product approval and pass the TAS 110 wind-driven rain test, which is about the sideways downpours that push water up under a cap.

Ridge vent Typical cost
Ridge vent installed About $300 to $650, most around $500
Labor share About $100 to $400 of that
Perforated white aluminum soffit panels under the eave of a stucco home with a white metal roof above

Soffit Intake Vents

A ridge vent can only pull out air that comes in somewhere lower down, usually at the soffit. The code says blocking and insulation must not cut off the airflow at eave vents, and wants at least 1 inch of clear space between the insulation and the roof sheathing at each vent. Ask the roofer to check from the attic that the soffit vents actually connect. Cost guides put soffit vents at about $2 to $10 per linear foot, or $315 to $465 for a typical job.

Spray foam insulation sprayed on the underside of a roof deck between rafters in an attic

Unvented Attics With Spray Foam

The alternative to venting is sealing: spray foam goes on the underside of the roof deck, the ridge and soffit vents are closed, and the attic becomes part of the conditioned house. The code allows an unvented attic only when the space is fully inside the building's thermal envelope, no Class I vapor retarder sits on the ceiling side, and the insulation meets the code's condensation-control rules.

Spray foam Cost and R-value
Open-cell foam About $1.50 to $3.50 per square foot, R-3.5 to R-3.7 per inch
Closed-cell foam About $3.00 to $5.00 per square foot, R-5 to R-7 per inch
Close view of the underside of a metal roof panel over underlayment with beads of moisture at a lap in an attic

Condensation Control Under Metal Panels

Metal panels cool quickly after sunset, and humid air that reaches cold metal can condense on it. Where panels sit on purlins with no solid deck underneath, as on some porches, sheds and mobile home roof-overs, that moisture can drip into the space below. Airflow under the panels, a vapor-tight layer or an insulated assembly reduces it. If you see drips from a metal roof on a dry morning, ask the roofer to check for condensation before chasing a leak.

Raised seams of a new bronze standing seam metal roof running up to the ridge

Why Pompano Beach homeowners call Pompano Metal Roofing

  • One independent roofer per request, never a call list
  • Ask for tear-off, deck repair and permit as separate lines
  • No fee to homeowners for the referral or the estimate
  • Your details go to that one roofer and nobody else

Get a free metal roofing estimate

Free for homeowners. One local contractor contacts you.

Metal Roof Ventilation Requirements in the Florida Code

Florida's Residential Code sets the attic ventilation rules for homes in Section R806. The Building Code sends roof ventilation to its own Section 1203.2 and the vent maker's instructions.

  • Basic ratio

    Net free ventilating area of at least 1/150 of the vented attic space.
  • Reduced ratio

    1/300 is allowed when 40% to 50% of the vent area is high, within 3 feet of the ridge, and the rest is in the bottom third of the attic.
  • Openings

    Between 1/16 and 1/4 inch at their narrowest, or screened to that size, and protected from rain, birds and rodents.
  • Clearance

    At least 1 inch of air space between insulation and sheathing at the vents.

Worked through for a 1,500 square foot attic (our arithmetic, not a design): the basic ratio needs 10 square feet of net free area. The reduced ratio needs 5 square feet, with 2 to 2.5 square feet of it at the ridge and the rest at the soffits. Ask the roofer to show the net free area count on the quote.

See metal roof leak repair if water is coming in at the ridge cap during storms.